mini is more. puls gmbh, arabellastrasse 15, 81925 munich tel. +49.(0)89.9278-244, fax: +49.(0)89.9278-299 sales@puls-power.com, http://www.puls-power.com puls does it again: practical, versatile and reliable like the silverline ? yet small like no other. miniline ml95.100 adjustable output voltage up to dc 24-28v puls overload design? (high output overload capability) 115/230v auto select input limited power source, nec class 2 and hazardous location class i div. 2 mounted and connected in record time, no tools required world-wide approvals (ul, en, csa) for industry and office/home tiny: wxhxd = 73 x 75 x 103mm with dc 24-28v / 95w ml95e100/040629 data sheet
x input input voltage ac 100-120/220-240v (auto select), 47...63 hz (ac 85...132v / ac 184...264v, dc 220...375v n= + and l= - ) input current <2.0 a (@ ac 100v in , 95 w p out ) <0.95 a (@ ac 220v in , 95 w p out ) external fusing not required, un it provides internal fuse (t3a15h, not accessible) transient immunity transient resi stance acc. to vde 0160 / w2 (750v/ 1.3 ms), over entire load range hold-up time (see diagram below) >40 ms @ ac 230v, 24.5v / 3.9 a >20 ms @ ac 196v, 24.5v / 3.9 a >20 ms @ ac 100v, 24.5v / 3.9 a x efficiency, reliability efficiency losses typ. 90% (ac 230 v, 24.5 v / 3.9 a) (see also diagram below) typ. 10.5 w (ac 230v, 24.5 v / 3.9 a) mtbf (reliability) appr. 500.000 h acc. to siemensnorm sn 29500 (24.5 v / 4.2 a, ac 230 v, t amb = +40 c) prior to shipment, every unit undergoes the following tests in order to isolate any defective units which might suffer an early failure: run-in / burn-in (full load, t amb = +60c, on/off cycle) functional test (100 %) x construction, mechanics, installation robust plastic housing (us patent no. d442, 923s), fine ventilation grid on three housing sides to keep out small parts (e.g. screws), ip20 dimensions and weight w x h x d depth incl. terminals: weight 73 mm x 75 mm x 103 mm + din rail (2.87in x 2.95in x 4.06in + din rail) 98 mm (3,85in) + din rail 360 g mounting orientation , or (cf. ?output?) ventilation/cooling free space f. cooling normal convection, no fan required recom'd.: 25 mm (1in) on sides with ventilation grid easy snap-on mounting onto the din-rail (ts35/7,5 or ts35/15). unit sits safely and firmly on the rail; no tools required even to remove connection by spring clamp terminals; uniformly firm hold, vibration-resistant and maintenance-free: 2 terminals per output connector size range flexible cable solid cable wire strip length 0.3-2.5mm 2 (28-12 awg) 0.3-4mm 2 (28-12 awg) ferrules admissible 6mm (0.24in) recommended x diagrams 0 5 10 15 20 25 30 0123456 24-28v output current i out [a] output voltage v out [v] 0 20 40 60 80 100 120 140 160 80 120 160 200 240 280 input voltage vacin [v] hold-up time [ms] pout=100w, typ. pout=100w, min. pout=50w, typ. pout=50w, min. 83 84 85 86 87 88 89 90 91 11,41,82,22,633,43,84,2 output current iout [a] efficiency [%] 1 1 5 v ac i n 2 3 0 v ac i n output characteristic v out /i out efficiency hold-up time with acin (@ v out = 24.5v, typ.) (at v out = 24.5v, typ. + min.) derating of output power 0 10 20 30 40 50 60 70 80 90 100 -10 0 10 20 30 40 50 60 70 mounting 85-132 v acin a-a a-b a-b 185-264 v acin a-a a-b a-b 220-375 v dcin a-a a-b a-b a a b t amb [c] p out [w] 95w, min. 95w, typ. x output output voltage preset dc 24-28v (adj. by front panel potentiometer) 24.5v 0.5% @ 3.9 a voltage regulation stat. <1% v out dyn. 1.5% v out over all ripple/noise <50mv pp (20 mhz bandw., 50 ? puls overload design?: no switch-off at overload/short-circuit, instead: up to 1.4 ? x environmental data, emc, safety ambient temperature range (measured 25 mm below unit) storage/transport operation -25c ... +85c -10c ... +70c (for dera ting see diagram below) humidity max. 95% (without condensation) electromagnetic emissions (eme) en 61000-6-3 (includes en 61000-6-4) class b (en 55011, en 55022) incl. output noise suppression en 61000-3-2 (pfc) electromagnetic immunity (emi) en 61000-6-2 (includes en 61000-6-1) safe low voltage: prot. class/degree: selv (en 60950, vde0100/t.410), pelv (en 50178) class 1 (en 60950) / ip20 (en 60529) the psu complies with all major safety approvals for eu (en 60 950, en 60204-1, en 50178), usa (ul 60950, e137006, ul508 listed, e198865), canada (can/csa-c22.2 no 60950 [cur], can/csa-c22.2 no. 14 [cul]), limited power source nec class 2 and hazardous location class i div. 2 according to ul1604. design details ? for your advantage: all terminals are easy to reach as mounted on the front panel. input and output are strictly apart from each other (input below, out- put above) and so cannot be mixed up. mounting and connection do not require any screwdriver product information (ml95.100), rev.: 29. june 2004. unless otherwise stated, specifications are valid for ac 230v input voltag e, +25c ambient temperature, and 5 min. run-in time. they are subject to change without prior notice. puls gmbh, arabellastra?e 15, d-81925 mnchen x tel: +49.(0)89.9278-244, fax: +49.(0)89.9278-299, e-mail: sales@puls-power.com x www.puls-power.com s p r i n g c l a m p s
|